B Braun Outlook 100, Recertified

Brand: B Braun
Item Number: BBHO100 R
Condition: Recertified
Log in to see your price List price: $585.00 EA
1

Description

The B. Braun Horizon Outlook 100 Infusion Pump is an easy-to-use device which helps to prevent IV medication errors. As the basis for our smart Extendable Platform Technology, it lets you plan for the future today.

Prevent IV Medication Errors
Promotes patient safety by helping to avoid accidental under- or overdosing using audible and visual alerts
Provides flexibility for each care area—ability to customize dose limits to your hospital drug formulary
Promotes clinician choice with dose limit override when limits are exceeded during manual programming and titration
Visually indicates dose selection with DoseGuard™ software

The Proper Balance of Safety and Ease of Use
Easy to learn
– Manual operation RATE, VOLUME, RUN
– Automatic Dose Rate Calculator
– Large, highly visible keys
Reduce nuisance air-in-line alarms with air-trapping cassette
Stackable modular design reduces bedside cord clutter and errors due to channel confusion
Comprehensive line of needle-free administration sets including UV light resistant tubing that protects drug efficacy

SPECIFICATIONS
– Mechanism: Volumetric, Positive Pressure Displacement Reservoir
– Width: 30.5 cm (12 in)
– Height: 11.4 cm (4.5 in)
– Depth: 22.2 cm (8.75 in)
– Weight: 5 kg (11 lbs)
– Power: 120 VAC, 3A, 60 Hz USA excluding accessories
– Grounding Resistance: Meets UL Standard 2601-1
– Leakage current: Meets or Exceeds UL Standard 2601-1
– Battery: 12 V sealed lead-acid battery
– Battery Operating
– Time: 3 hours at 125 mL/hr
– Rate Range: 0.1 to 999.9 mL/hr in 0.1 mL increments
– Micro Mode: 0.1 to 99.9 mL/hr in 0.1 mL increments
– Volume to be Infused Range: 0.1 to 9999.9 mL in 0.1 mL increments
– Variable Occlusion Pressure: 75, 100, 200, 300, 400, 500, and 750 mmHg
– KVO Rate: 3 mL/hr or selected rate whichever is lower
– Volumetric Accuracy: ± 5%
– Alarms: Air-in-Line, Bag Empty, Door Open, Downstream Occlusion,
– Hold time Exceeded, Low Battery, Plug-in, System Error,
– Upstream Occlusion, Check Set, DoseGuard™ Alert Memory: Permanent data retention after the pump is turned off unless alternative Data Retention Defaults have been selected in the Biomed Options
– Tubing: Horizon® Pump Sets
– Modes/Features: Dose Mode with Drug Menu and DoseGuard™ dose limits,
– Primary and Piggyback Modes, Set Time and Volume, Schedule Next Run, Profile Mode for TPN, Program Mode, q(x) Mode, Site Trend, Variable Occlusion Pressure, Micro Mode, Epidural Mode

REFERENCE LIBRARY

Product Brochure

WHAT’S INCLUDED